APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22017 Issued:2015-10-09
Revised:2015-10-14
Style 22017 Bonded or Laminated Flat Ribbon Cable

Rating60 deg C, 80 deg C, 30 Vac, 150 Vac.
Conductor36-10 AWG solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure, The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to the PVC covering to form a flat ribbon type cable or twisted to form a round cable. Parallel pairs may be shielded. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
Inner CoveringOptional, extruded PVC or one or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional.
Outer CoveringOptional, PVC, 5 - 80 mils; Or PTFE, 2 - 80 mils; Or one or two layers of 1 mils polyester film with polyester adhesive.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial- Internal Wiring with No Flame Rating.

UL and the UL Logo are trademarks of UL LLC © 2024