APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22018 Issued:2015-10-15
Revised:2019-10-30
Style 22018 Multiple Conductor Cable employing a Non-Extruded Covering

Rating105 deg C,30 Vac, Horizontal Flame.
Conductor50 AWG - 10 AWG, Solid or Stranded, Metal Coated.
InsulationExtruded FEP - 4.5 mils minimum average thickness, 4.0 mils minimum at any point
AssemblyTwo Insulated Conductors, with optional PTFE Tape wrap around the pair, laid Parallel with Shield and Overall Covering
ShieldMetal in accordance with Standard
CoveringNon-Extruded Heat Sealed Polyester Tap - Minimum thickness 0.5 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.