APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22029 Issued:2015-12-30
Revised:2015-12-29
Style 22029 Multiple-conductor cable using non-integral jacket

Rating105 deg C,-20 deg C,300 Vac FT2 flame.
ConductorTwo to six No. 16 - 26 AWG conductors; Different conductor sizes may be employed in one cord.
InsulationPVC, 15 mils min average, 13 mils minimum at any point.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified.
JacketPVC, 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024