APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22031 Issued:2016-02-19
Revised:New
Style 22031 Multiple-conductor cable using non-integral jacket

Rating80 deg C,300 Vac, Cable flame, Sun Res. (Optional).
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to eight insulated conductors laid flat or two or more twisted singles or groups of twisted singles, may be twisted together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form.
ShieldOptional.
CoveringOptional - A 10 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded TPU.
Diameter of core assembly under jacket*Minimum average thicknessMinimum thickness at any point
0.700 inches or less30 mils24 mils
0.701-1.00045 mils36 mils
1.001-1.50060 mils48 mils
1.501-2.50080 mils64 mils
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024