APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22040 Issued:2016-06-09
Revised:New
Style 22040 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C,600 Vac Horizontal flame.
Conductor32 AWG - 2000 kcmil, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded TPU and PVC (Inseparable Layers)
Major diameter in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0 ¿ 0.7003024
0.701 ¿ 1.0004536
1.001 ¿ 1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024