|
Rating | 80 deg C,1000 Vac Horizontal flame. |
|
Conductor | 32 AWG - 2000 kcmil, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Jacket | Extruded TPU and PVC (Inseparable Layers) |
| Major diameter in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0 ¿ 0.700 | 30 | 24 |
| 0.701 ¿ 1.000 | 45 | 36 |
| 1.001 ¿ 1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|