APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22044 Issued:2016-06-27
Revised:New
Style 22044 Multiple Conductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with the manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together; or singles or groups of singles, may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldA metal shield(s) shall be provided.
CoveringOptional.
JacketExtruded TPE.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.300 inch or less68 mils54 mils
0.301-0.700 inch78 mils62 mils
0.701-1.000 inch90 mils72 mils
1.001-1.500 inch105 mils84 mils
1.501-2.500 inch120 mils96 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.