APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22057 Issued:2016-09-12
Revised:2019-10-11
Style 22057 Multiconductor cable With Extruded Non-integral Jacket

Rating90 deg C,300 Vac, Cable flame. Horizontal flame
Conductor38 AWG - 4 AWG, solid or stranded.
InsulationExtruded FEP, 9 mils minimum average thickness, 8 mils minimum at any point.
CoveringOptional, extruded XLPE, 22 mils minimum average thickness, 17 mils minimum at any point.
AssemblyThe cable consists of two insulated conductors, may be laid parallel to form flat, oval or round cables
ShieldOptional.
JacketExtruded PVC
Dia. of Cable Under Jacket in Inchsmils min averagemils min at any point
0.700 or less3124
0.701 - 1.0004536
1.001 - 1.5006048
1.501 - 2.5008064
Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024