APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22063 Issued:2016-10-26
Revised:New
Style 22063 Multiple-conductor cable using non-integral jacket.

Rating80 deg C,300 Vac Horizontal flame.
Conductor32 AWG minimum, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mils or heavier covering may be extruded over the conductor assembly.
JacketExtruded TPU, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring- for use with Material Handling Equipment where the cables are protected by Equipment Structure and where the acceptability is determined by UL LLC.