| Rating | 75 deg C,30 Vac ; Moisture Res 75 (required); Sunlight Res (required). |
|
| Conductor | 20 AWG - 16 AWG, stranded. |
|
| Insulation | Extruded XLPE,20 mils minimum average thickness, 18 mils minimum thickness at any point. See Facing page for compound. |
|
| Assembly | Two to five twisted singles. Lay not specified. Barrier layer and/or fillers optional. |
|
| Jacket | Extruded PVC, 40 mils minimum average thickness, 36 mils minimum thickness at any point. R/C (QMTT2) suitable for 720hr Sunlight Resistant or see Facing page for compound. |
|
| Covering | Optional Foamed Polyolefin; supplemental flotation layer. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Special; for use floating or submerged in water, no flame rating required. |
|