APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22069 Issued:2016-12-06
Revised:2017-03-06
Style 22069 Multiple-conductor cable using non-integral jacket

Rating80 deg C,30 Vac Horizontal flame; Oil Res 60 (optional), Sunlight Resistance(optional).
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo to four parallel, or two or more twisted insulted singles or groups of twisted singles twisted together or groups of twisted singles may be laid parallel to form flat or oval cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum.
ShieldOptional
JacketExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of electronic equipment in Class 2 systems only.

UL and the UL Logo are trademarks of UL LLC © 2024