Rating | 80 deg C, 30 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complies with manufacturer's Procedure. |
|
Assembly | Two or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Each insulated conductor may be laid parallel and then 2 or more jackets may be co-extruded over each insulated conductor. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. Extruded PVC, 5 mils minimum thickness at any point, over the assembly or groups of singles. |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded PVC. If parallel construction is rippable, the measurements are made after ripping. |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.250 inch or less | 20 mils | 16 mils |
| 0.251-0.424 inch | 30 mils | 24 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| * = Major diameter if flat or oval construction. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring in Class 2 Circuits only. |
|