APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22096 Issued:2017-06-27
Revised:New
Style 22096 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Insulated ConductorLabeled or complies with manufacturer's Procedure.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Each insulated conductor may be laid parallel and then 2 or more jackets may be co-extruded over each insulated conductor. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional. Extruded PVC, 5 mils minimum thickness at any point, over the assembly or groups of singles.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. If parallel construction is rippable, the measurements are made after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring in Class 2 Circuits only.