APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22099 Issued:2017-07-14
Revised:New
Style 22099 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional. A 10 mils thick or thicker, PVC covering.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.350 inch or less20 mils16 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch40 mils32 mils
1.001-1.500 inch54 mils43 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.