APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2210 Issued:1959-05-01
Revised:2011-09-15
Style 2210 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, FT-2 Flame.
Conductor18 AWG - 10 AWG, stranded, consists of 0.0049 in - 0.010 inch conductor strands (18 - 14 AWG) or 0.0049 in - 0.016 inch conductor strands (12 -10 AWG).
InsulationExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
18-12 AWG30 mils27 mils
10 AWG45 mils40 mils
AssemblyFive-conductor, same as flexible cord type SJT.
JacketExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
18-14 AWG30 mils24 mils
12 AWG45 mils36 mils
10 AWG60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting cord.

UL and the UL Logo are trademarks of UL LLC © 2024