|
| Rating | 80 deg C,30 Vac Cable flame, Sunlight Resistance |
|
| Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. 40 AWG minimum. |
|
| Assembly | Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Barrier layers, binders over groups of conductors and/or the complete conductor assembly, and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over groups of conductors and/or over the complete conductor assembly. |
|
| Shield | (Optional) May be provided over groups of conductors and/or over the complete conductor assembly. |
|
| Jacket | Extruded PVC. |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 30 mils | 24 mils |
| 0.426-0.700 inch | 45 mils | 36 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.000-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 inch and larger 140 mils 112 mils
* - Major diameter if cable is flat or oval |
|
| Parallel Strength Member | Integrated to jacket. The steel wire is covered by minimum 18 mils thickness PVC. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring or external interconnection. |
|