Rating | 90 deg C, 300 V, FT2 flame; Moisture Res 60C (required); Sunlight Res (required). |
|
Conductor | 14 AWG and 24-25 AWG, solid or stranded. |
|
Insulation | Extruded PP, See facing Page for compound |
| Conductor size (AWG) | Minimum average thickness | Minimum thickness at any point |
| 24 - 25 | 12 mils | 10 mils |
| 14 | 30 mils | 27 mils |
| |
|
Assembly | The cable consists of two No. 14 AWG insulated conductors and three No. 24 AWG or 25 AWG insulated conductors cabled together with an optional filler and overall FRPE jacket. |
|
Fillers | Optional. |
|
Jacket | Extruded FRPE, See facing Page for compound |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.500 inch or less | 30 mils | 24 mils |
| |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Special - External Wiring with FT2 Flame Rating. |
|