APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22119 Issued:2017-09-11
Revised:2017-09-14
Style 22119 Multi-conductor cable with extruded insulation and extruded, non-integral jacket

Rating90 deg C, 300 V, FT2 flame; Moisture Res 60C (required); Sunlight Res (required).
Conductor14 AWG and 24-25 AWG, solid or stranded.
InsulationExtruded PP, See facing Page for compound
Conductor size (AWG)Minimum average thicknessMinimum thickness at any point
24 - 2512 mils10 mils
1430 mils27 mils
AssemblyThe cable consists of two No. 14 AWG insulated conductors and three No. 24 AWG or 25 AWG insulated conductors cabled together with an optional filler and overall FRPE jacket.
FillersOptional.
JacketExtruded FRPE, See facing Page for compound
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.500 inch or less30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - External Wiring with FT2 Flame Rating.

UL and the UL Logo are trademarks of UL LLC © 2024