APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22121 Issued:2017-09-27
Revised:New
Style 22121 Multiple conductor cable with non-integral jacket

Rating80 deg C, 30 Vac.
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Barrier layers, binders over groups of conductors and/or the complete conductor assembly, and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
InsulationLabeled or complying with manufacturer's Procedure.
ShieldOptional.
CoveringInner - Optional.
JacketExtruded TPE, 23 mils minimum average thickness, 18 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - For use in electronic equipment in Food and Beverage production, no flame rating required.

UL and the UL Logo are trademarks of UL LLC © 2024