APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22129 Issued:2017-10-23
Revised:2023-07-18
Style 22129 Multiple-Conductor Cable using Non-Integral Jacket

Rating80 deg C,30 Vac Horizontal Flame, Cable Flame.
ConductorSolid or stranded
Insulated ConductorLabeled or complying with AWM Procedure having a minimum rating of 80 deg C
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket (inch)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.400 inch or less1512
0.401 - 0.7003024
0.701 - 1.0004032
1.001 - 1.5005443
Overall braidPolyester.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection wiring of electronic equipment in Class 2 circuits only.