Rating | 80 deg C,30 Vac Horizontal Flame, Cable Flame. |
|
Conductor | Solid or stranded |
|
Insulated Conductor | Labeled or complying with AWM Procedure having a minimum rating of 80 deg C |
|
Assembly | Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket (inch) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.400 inch or less | 15 | 12 |
| 0.401 - 0.700 | 30 | 24 |
| 0.701 - 1.000 | 40 | 32 |
| 1.001 - 1.500 | 54 | 43 |
|
Overall braid | Polyester. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection wiring of electronic equipment in Class 2 circuits only. |
|