APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22139 Issued:2017-11-07
Revised:2017-11-29
Style 22139 Multi-conductor cable with extruded non-integral jacket.

Rating105 deg C, 600 Vac; Cable flame; Oil Res 75 (optional); -40C (optional).
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketTPE
Diameter of cable under jacket (in)Minimum Average thickness (mils)Minimum thickness at any point (mils)
0 - 0.7004536
0.701-1.0006048
1.001-1.5008064
1.501-2.50011088
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.