APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2214 Issued:1959-05-01
Revised:2012-10-10
Style 2214 SPT-1 Cord.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor22 AWG - 16 AWG, stranded, tinned or bare copper.
InsulationIntegral with Jacket. Extruded PVC, 30 mils minimum average, 27 mils minimum at any point.
AssemblyTwo conductors, same as type SPT-1.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of X-Ray Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024