APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22140 Issued:2017-12-08
Revised:New
Style 22140 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating150 deg C,90 Vac Cable flame.
InsulationLabeled or complying with Manfacturer's AWM procedure.
AssemblyTwo insulated conductors laid parallel or two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder and/or fillers may be employed.
ShieldOptional
CoveringOptional
JacketExtruded FEP
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0. 250 or less86
0.251-0.350108
0.351-0.5001310
0.501-0.7001512
0.701-1.5002016
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External interconnection of electronic equipment.