APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22144 Issued:2018-02-06
Revised:2018-03-02
Style 22144 Muliple-conductor cable with extruded non-integral jacket.

Rating80 deg C, No Voltage Specified; Cable flame; 60 deg C wet (required); 60 deg C Oil Res (Optional).
InsulationLabeled or complying with manufacturer's AWM Procedure with minimum rating of 300V, 80C dry, 60C wet. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
Barrier LayerOptional barrier layer - may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. Optional barrier layer. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
CoveringOptional - Thermoplastic.
ShieldOptional. Metal braid or tape may be provided under the overall jacket.
JacketTPU
Dia.under jacket (inches)Minimum avg thickness (mils)Minimum thickness at any point (mils)
0.700 or less4838
0.701-1.0006048
1.001-1.508064
1.501-2.5011088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024