APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22147 Issued:2018-02-20
Revised:2021-01-19
Style 22147 Bonded flat ribbon cable

Rating80 deg C, 150 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 200 insulated singles, twisted pairs, triads or quads, laid parallel in one plane, bonded together in such a fashion to form a flat ribbon-type cable. May also consist of parallel pairs, or groups of parallel pairs twisted together. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
ShieldOptional - Al/PET tape provided over the conductor assembly.
CoveringTinned copper braid provided over the conductor assembly or over the Al/PET tape if provided.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025