APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22154 Issued:2018-04-25
Revised:New
Style 22154 Multi-conductor cable with extruded non-integral jacket.

Rating90 deg C, 3000 Vac, Horizontal flame.
InsulationLabeled. Insulated singles may employ magnet wire conductors, but are not required to be magnet wire.
AssemblyTwo or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. A binder tape(s) and/or fillers may be employed. Binder tape(s) and shield(s) may be employed over groups of conductors or over the cable core.
ShieldOptional - metal tape(s) and/or braid(s) provided over groups of conductors or over the cable core.
CoveringOptional.
JacketExtruded TPU, 95 mils minimum average thickness, 76 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.