APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22158 Issued:2018-05-24
Revised:New
Style 22158 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 60 Vac, Cable flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationExtruded PFA, 6 mils minimum average thickness, 5 mils minimum at any point.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
2.500 inch or less15 mils12 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring in Class 2 Circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024