APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22160 Issued:2018-05-24
Revised:2023-05-19
Style 22160 Multi-conductor cable with extruded non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM file
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional, metal tape(s) provided over the cable cored.
BraidOptional, metal braid(s) provided over the metal tape(s).
Inner JacketExtruded PVC, 18 mils minimum average thickness, 14 mils minimum thickness at any point.
Outer JacketExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point. The outer jacket shall be provided over the inner jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024