Rating | 75 deg C, 30 Vac, Cable flame. |
|
Conductor | 32 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded LDPE, extruded simultaneously flat shaped insulation with parallel two conductors, having 7 mils minimum average thickness, 6 mils minimum thickness at any point and 10 mils minimum distance between conductors. May be small holes for drain wire. |
|
Assembly | Two to eight units cabled twisted together. Each unit consists of one insulation with parallel two conductors, required tape shield with adhesive, filler, tape and/or tape binders with adhesive.
A binder, fillers and/or tapes for overall assembly may be employed. |
|
Shield | Required. |
|
Jacket | Extruded PVC. |
| Diameter of Cable Under Jacket (inches) | Minimum Average Thickness (mils) | Minimum Thickness at any point (mils) |
| 0.400 or less | 24 | 19 |
| 0.401 - 0.700 | 30 | 24 |
| 0.701 - 1.500 | 45 | 36 |
| 1.501 - 2.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|