APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22168 Issued:2018-06-06
Revised:2018-07-25
Style 22168 Multi conductor cable with extruded non-integral jacket.

Rating75 deg C, 30 Vac, Cable flame.
Conductor32 AWG - 20 AWG, solid or stranded.
InsulationExtruded LDPE, extruded simultaneously flat shaped insulation with parallel two conductors, having 7 mils minimum average thickness, 6 mils minimum thickness at any point and 10 mils minimum distance between conductors. May be small holes for drain wire.
AssemblyTwo to eight units cabled twisted together. Each unit consists of one insulation with parallel two conductors, required tape shield with adhesive, filler, tape and/or tape binders with adhesive. A binder, fillers and/or tapes for overall assembly may be employed.
ShieldRequired.
JacketExtruded PVC.
Diameter of Cable Under Jacket (inches)Minimum Average Thickness (mils)Minimum Thickness at any point (mils)
0.400 or less2419
0.401 - 0.7003024
0.701 - 1.5004536
1.501 - 2.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024