APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22170 Issued:2018-07-31
Revised:2018-08-30
Style 22170 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating90 deg C,300 Vac, Cable flame.
Conductor40 AWG - 20 AWG, solid or stranded.
InsulationExtruded Polyolefin blend, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Flat, extruded top and/or bottom layers may form ridges over conductors, 35mils minimum distance between conductors. See Facing Page.
AssemblyTwo or more conductors, Flat Cable folded or spiraled layers. Section may be slit into singles, Fillers optional. Overall cable may be flat or round.
ShieldOptional.
JacketExtruded Polyolefin or FRPE, See Facing Page.
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
Cable is flat or round.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal or Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025