Rating | 90 deg C,300 Vac, Cable flame. |
|
Conductor | 40 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded Polyolefin blend, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Flat, extruded top and/or bottom layers may form ridges over conductors, 35mils minimum distance between conductors. See Facing Page. |
|
Assembly | Two or more conductors, Flat Cable folded or spiraled layers. Section may be slit into singles, Fillers optional. Overall cable may be flat or round. |
|
Shield | Optional. |
|
Jacket | Extruded Polyolefin or FRPE, See Facing Page. |
| Diameter of core assembly under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
| 1.501-2.500 | 80 | 64 |
| Cable is flat or round. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External or Internal Wiring. |
|