APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22172 Issued:2018-08-13
Revised:2018-08-14
Style 22172 Flat Cable

Rating80 deg C, 30 Vac Horizontal flame.
Conductor40 AWG - 10 AWG, material not specified.
InsulationExtruded Solid FRPE or PP, 5 mils minimum average thickness, 4 mils minimum at any point thickness.
AssemblyTwo through Fifty insulated singles laid parallel, same or mixed AWG.
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils minimum thickness at any point. May have web between insulated singles.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2025