APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22181 Issued:2018-10-19
Revised:New
Style 22181 Multiple-conductor cable using non-integral jacket and non-extruded covering

Rating80 deg C,30 Vac, Cable flame, VW-1 flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated conductors. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC.
Diameter of round assembly under jacket@Minimum average thicknessMinimum thickness at any point
0-1.500 inch12 mils10 mils
1.501-2.500 inch15 mils12 mils
@The equivalent diameter of a flat assembly is calculated as 1.1284x(TW)^1/2 in which T is the thickness of the assembly under the jacket and W is the width of the assembly under the jacket.
CoveringPolyester braid, 8 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring for use in or with Class 2 systems.

UL and the UL Logo are trademarks of UL LLC © 2024