APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22186 Issued:2018-10-22
Revised:2018-10-23
Style 22186 Multiconductor cable with extruded non-integral jacket.

Rating80 deg C,30 Vac, Horizontal flame.
Conductor36 AWG minimum. Solid or Stranded.
InsulationLabeled or complying with this manufacturers AWM Procedure
AssemblyTwo or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded TPE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.00 inch45 mils36mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.500 inch and larger110 mils88 mils
BraidOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring