Rating | 90 deg C, 1000 Vac, Horizontal Flame. |
|
Conductor | 40 AWG minimum, solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer, binders and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional, extruded over conductor assembly. |
|
Shield | Optional |
|
Jacket | Extruded TPU ; |
| Diameter of core assembly under jacket | Minimum average thickness mils | Minimum thickness at any point mils |
| 0.700 inch or less | 30 | 24 |
| 0.701-1.000 inch | 45 | 36 |
| 1.001-1.500 inch | 60 | 48 |
| 1.501-2.500 inch | 80 | 64 |
| 2.501-4.500 inch | 110 | 88 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|