APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22195 Issued:2018-12-12
Revised:2018-12-13
Style 22195 Multiple Conductor Cable with Extruded Insulation and Non-Extruded Covering

Rating105 deg C,300 Vac, FT-2 flame.
ConductorNo. 18-14 AWG, Stranded Round, Same as Listed Type SPT-1.
InsulationAny Labeled Extruded PVC insulation style, 40 mils minimum average thickness, 37 mils minimum thickness at any point having a minimum rating of 105C, 300Vac. Conductor requirements same as Listed SPT-1.
CoveringNon-Extruded Nylon Braid with 12 mils minimum average thickness. See Facing page for Details.
AssemblyTwo (2) or 3 insulated conductors twisted together with overall braid. Length of lay of conductors is 2 inches.
StandardFlexible Cords and Cables, UL 62.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. Similar to listed type SPT-1.