APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22197 Issued:2018-12-13
Revised:New
Style 22197 Multi-conductor cable with extruded insulation and overall non-extruded covering

Rating105 deg C,600 Vac, FT2 flame.
ConductorNo. 18-14 AWG, Stranded Round, Same as Listed Type SPT-1.
InsulationAny Labeled Extruded PVC insulation style, 40 mils minimum average thickness, 37 mils minimum thickness at any point having a minimum rating of 105C, 300Vac. Conductor requirements same as Listed SPT-1.
AssemblyTwo (2) or 3 insulated conductors twisted together with overall braid. Length of lay of conductors is 2 inches.
CoveringNon-extruded Nylon Braid, 12 mils minimum average thickness. See Facing Page for details.
StandardFlexible Cords and Cables, UL 62.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. Similar to listed type SPT-1.