Rating | 80 deg C,150 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 10 AWG, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable. |
|
Assembly | Two to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously laminated to the covering to form a flat ribbon type cable or twisted to form a round cable. Parallel pairs may be shielded. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable. For flat cable, 50 mils minimum distance between conductors or conductor and outer edges. |
|
Inner Covering | Optional, extruded PVC or one or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified. |
|
Shield | Optional |
|
Outer Covering | Optional, one or two layers of Polyimide Film 1 - 2 mils thick with 4 mils Vinyl Acetate / Polyester Polyolefin combination adhesive; PVC, 5 - 80 mils; Or PTFE, 2 - 80 mils; Or one or two layers of 1 mils polyester film with polyester adhesive. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|