APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22202 Issued:2019-02-22
Revised:2021-01-20
Style 22202 Multiple-conductor cable using non-integral jacket

Rating105 deg C,150 Vac Cable flame; 720hr Sunlight Resistance.
ConductorMinimum 28 AWG, stranded, tinned or bare copper. Mixed AWG sizes may be employed.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors
JacketPVC, minimum thickness same as SJTW. Any recognized component (QMTT2) PVC compound 720 hour sunlight resistance compound and/or Facing Page for other Designated compound.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0-0.350 inch30 mils24 mils
0.351-0.450 inch45 mils36 mils
0.451-0.550 inch60 mils48 mils
0.551-0.900 inch80 mils64 mils
0.901-1.25 inch95 mils76 mils
1.26-1.50 inch110 mils88 mils
1.51-2.00 inch125 mils100 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024