APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22204 Issued:2019-01-25
Revised:New
Style 22204 Multiple-conductor cable with extruded non-integral jacket

Rating105 deg C, 300 Vac, FT2 flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors assembled in accordance with the Standard. Tape(s), shield(s) and fillers shall be optional.
ShieldOptional - one or more Al/polyester tape(s), All metal tape(s) or metal braid(s) provided under the overall jacket.
JacketExtruded PVC.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - External interconnection for lighting applications where the required flame rating is FT2. The final acceptance of the combination has been determined by UL LLC.

UL and the UL Logo are trademarks of UL LLC © 2024