APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22209 Issued:2019-03-06
Revised:2019-03-28
Style 22209 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded XLPE, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
AssemblyOne or two insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldRequired - Metal Braid with 85% coverage, or a Foil shield and drain wire
JacketExtruded PVC, 28 mils minimum average thickness, 22 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024