APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22223 Issued:2019-03-29
Revised:2019-04-01
Style 22223 Multiple Conductor Cable Employing Extruded Non-Integral Jacket

Rating80 deg C, 1000 Vac.
Conductor36 AWG min., Solid or Stranded Round.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU - 30 mils minimum average thickness, 24 mils minimum thickness at any point.
BraidOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial, No Flame Rating, where the acceptability is determined by UL LLC or in the end use application.

UL and the UL Logo are trademarks of UL LLC © 2024