APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22226 Issued:2019-04-29
Revised:2019-05-07
Style 22226 Multiple Conductor cable with non-integral extruded jacket

Rating90 deg C, 1000 Vac, VW-1 Flame, Cable Flame
InsulationLabeled or complying with manufacturers AWM procedure
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Barrier layers, binders over groups of conductors and/or the complete conductor assembly, and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldMetal Coated Braid
CoveringOptional
SeparatorOptional
JacketExtruded TPU
Diameter under Jacket in inchesmils min average thicknessmils min at any point
0-1.0004743
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024