APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22227 Issued:2019-05-02
Revised:2019-08-12
Style 22227 Multiconductor cable with extruded non-integral jacket

Rating300 deg C, 600 Vac; Oil Res 60C; Oil Res 80C; Gasoline Res; Cable Flame; VW-1
InsulationLabeled or complying with AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers and metal shield are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded ECA
Diameter under Jacketminimun average thickness (mils)mininimum thickness at any point (mils)
0-0.350 inch108
0.351-0.500 inch1310
0.501-0.700 inch1512
0.701-1.500 inches2016
1.501-2.500 inches3024
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024