APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22228 Issued:2019-05-10
Revised:2019-05-23
Style 22228 Multi-Conductor Cable with Non-extruded Covering

Rating80 deg C,30 Vac Horizontal flame.
ConductorSolid or stranded
Insulated SinglesLabeled or complying with manufacturer's AWM Procedure having a minimum rating of 80°C and 30 V.
AssemblyTwo or more singles, twisted pairs of groups of twiste d singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified.
ShieldRequired, AL or AL/Polyester tape shield
CoveringNon-extruded PI tape, 1 mil minimum average thickness, 0.8 mil minimum thickness at any point, covering and shield is bonded with TPU adhesive.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024