APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22232 Issued:2019-05-15
Revised:New
Style 22232 Multiconductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 600 Vac, Cable Flame, VW-1 Flame
InsulationLabeled or complying with AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer, tape, and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU - Consisting of a nonseparable Single Layer or Dual Layer with an intermediate textile or aramid braid reinforcement layer. The thickness of each individual layer is not specified.
Diameter under Jacketmils min averagemils min at any point
0-1.000in4536
1.001-1.500in6048
1.501-2.500in8064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.