APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22242 Issued:2019-05-28
Revised:New
Style 22242 Multiple-conductors cable using non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Each insulated conductor or group of insulated conductors may be laid parallel and then 2 or more jackets may be co-extruded over insulated conductors. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC, 13 mils minimum average thickness, 10 mils minimum thickness at any point. If parallel construction is rippable, the measurements are made before and after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024