APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22247 Issued:2019-05-22
Revised:New
Style 22247 Multiconductor Cable with Extruded Non-Integral Jacket

Rating60 deg C,600 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded FRPE, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.