APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2225 Issued:1959-05-01
Revised:2011-12-06
Style 2225 Parallel cable with extruded integral insulation and jacket

Rating80 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
ConductorFour No. 20, 18 or 16 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 45 mils min average, 40 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of lighting circuits in electric refrigerators where exposed to temperatures not exceeding 80 deg C; or Internal wiring of lighting circuits in electric refrigerators where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024