Rating | 75 deg C, 30 Vac, Cable Flame. |
|
Conductor | 50 - 2 AWG solid or stranded, in accordance with the Standard. |
|
Insulation | Extruded solid PE with minimum average thickness 10 mils, minimum thickness at any point 9 mils. |
|
Assembly | Two or more conductor pairs employing an Al/polyester tape over each pair, optional fillers, overall Al/polyester tape shield, overall metal braid and overall jacket. |
|
Inner Shield | An Al/polyester tape shall be provided over each insulated conductor pair. |
|
Outer Shield | An Al/polyester tape shall be provided around the completed core. Additional metal tapes may be provided. |
|
Braid | A metal braid shall be provided over the overall shield and under the overall jacket. Additional metal braids may be provided. |
|
Jacket | Extruded TPU (PUR) |
| Diameter of cable under jacket in inches | Minimum average thickness in mils | Minimum thickness at any point in mils |
| 0.400 or less | 24 | 19 |
| 0.401-0.700 | 30 | 24 |
| 0.701-1.500 | 45 | 36 |
| 1.501-2.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|