APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22255 Issued:2019-08-05
Revised:2021-10-11
Style 22255 Multi-conductor cable with extruded non-integral jacket

Rating75 deg C, 30 Vac, Cable Flame.
Conductor50 - 2 AWG solid or stranded, in accordance with the Standard.
InsulationExtruded solid PE with minimum average thickness 10 mils, minimum thickness at any point 9 mils.
AssemblyTwo or more conductor pairs employing an Al/polyester tape over each pair, optional fillers, overall Al/polyester tape shield, overall metal braid and overall jacket.
Inner ShieldAn Al/polyester tape shall be provided over each insulated conductor pair.
Outer ShieldAn Al/polyester tape shall be provided around the completed core. Additional metal tapes may be provided.
BraidA metal braid shall be provided over the overall shield and under the overall jacket. Additional metal braids may be provided.
JacketExtruded TPU (PUR)
Diameter of cable under jacket in inchesMinimum average thickness in milsMinimum thickness at any point in mils
0.400 or less2419
0.401-0.7003024
0.701-1.5004536
1.501-2.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024