Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 50 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure, The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable. |
|
Assembly | Two or more insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together to form a flat ribbon type cable or twisted to form a round cable. Parallel pairs may be shielded. Manufacturer shall maintain a record of all singles used in each cable. May include mixed AWG sizes. |
|
Shield | Optional. |
|
Covering | Inner Covering. PTFE film, 0.7 mil min at any point. |
|
Shield | Optional. |
|
Covering | Outer Covering. Wrap Polyester film with polyester adhesive, one or two sheets, each sheet is 0.5 mil min at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|