APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2226 Issued:1959-05-01
Revised:2012-04-12
Style 2226 Parallel cable with extruded integral insulation.

Rating90 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
ConductorNo. 20, 18 or 16 AWG consisting of 30 AWG or smaller tinned or bare copper strands.
InsulationExtruded PVC, 45 mils min average, 40 mils minimum at any point.
AssemblyFour conductors, same as type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of lighting circuits in electric refrigerators where exposed to temperatures not exceeding 90 deg C; or Internal wiring of lighting circuits in electric refrigerators where exposed to air at a temperature not exceeding 90 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024